{"title":"Chromatotec","description":null,"products":[{"product_id":"chromatotec-airtoxic-btx-pid","title":"Chromatotec airTOXIC BTX PID","description":"\n\u003c!-- PDF Documents --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/Translation_document_LCSQA_-_UK-5.pdf?v=1793684192\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eLCSQA TRANSLATION DOCUMENT\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/tsp_a73_a73-B_a73_Exp_a76_airtoxic.pdf?v=1793684192\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eAIRTOXIC TECHNICAL DOCUMENT\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/shores_presentation_6_light.pdf?v=1793684192\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eSHORES PRESENTATION\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/EN14662_MCERTS_certificate_airTOXIC_2023.pdf?v=1793684191\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eEN14662 MCERTS CERTIFICATE\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003c!-- Product Description --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: #0d0c0c;\"\u003eDescription\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch3\u003eAnalysis of BTEX and 1,3-butadiene\u003c\/h3\u003e\n\n\u003cp\u003eA GC\/PID for automatic monitoring of BTEX in air, water and soils.\u003c\/p\u003e\n\n\u003cp\u003e\n  This instrument uses a port valve with a single absorbent trap, and a 30 meter metallic 0.28 mm ID column.\u003cbr\u003e\n  Minimum detection level as low as 10 ppt for application Benzene or 1,3-Butadiene in ambient air.\u003cbr\u003e\n  Miniaturization, sensitivity, mobility and flexibility are its main features.\u003cbr\u003e\n  Everything from the sample port up to the data storage is integrated in a 19″- rack 5U.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003e\u003cem\u003eMCERTS certified analyzer for benzene measurement following EN 14662-3 norms.\u003c\/em\u003e\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Programmed gradient temperature up to 202°c for the column oven and pressure\/flow control of the carrier gas.\u003cbr\u003e\n  Linearity on area with R² \u0026gt; 0.995\u003cbr\u003e\n  \u003cstrong\u003eEuropean range :\u003c\/strong\u003e 0.45 to 45 µg\/m3 = 0.1 to 14.5 ppb.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Before delivery the analyzer is tested for one week by our quality control department.\u003cbr\u003e\n  Photo ionization detector (PID), 10,6 eV lamp.\u003cbr\u003e\n  Self-cleaning of the lamp ensures high stability.\u003cbr\u003e\n  Bi-directional RS-232 C to transfer data and results to the internal computer.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Vistachrom software enables the user to view and store data on a industrial computer. It provides comfortable user-friendly utilities to recalculate, calibrate and export data and to configure the measurement.\u003cbr\u003e\n  The software allows the calculation of retention time, area, mass or concentration profiles, in any measuring unit.\u003cbr\u003e\n  LCD DISPLAY\u003cbr\u003e\n  \u003cstrong\u003eResults output :\u003c\/strong\u003e different communication protocols available.\n\u003c\/p\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003ch6\u003eTechnical Data\u003c\/h6\u003e\n\n\u003ctable class=\"product_layout_27\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth class=\"product_layout_26\" colspan=\"2\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eBTEX Analysis\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Up to 8 compounds, including Benzene, Toluene, Ethylbenzene, Xylenes (Ortho, Meta, Para), Cyclohexane, Styrene, with the option for 1,3-Butadiene and IAA.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eLower Detection Limit (LDL) in Automatic Mode\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          ≤ 0.01 ppb (0.0325 µg\/m³)\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDetection Range and Linearity for Benzene\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          3.25 to 3250 µg\/m³ (0-1000 ppb)\u003cbr\u003e\n          0.32 to 325 µg\/m³ (0-100 ppb)\u003cbr\u003e\n          0.032 to 32.5 µg\/m³ (0-10 ppb)\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eRelative Standard Variation (Precision)\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Better than 0.3% over 48 hours (Retention Time)\u003cbr\u003e\n          Better than 2% over 48 hours at 1 ppb (Concentration)\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eVariable Cycle Time\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          15, 20, 30 minutes\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"DiamondSci","offers":[{"title":"Default Title","offer_id":50103996219651,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/airtoxic.webp?v=1793684039"},{"product_id":"chromatotec-airmovoc-btx","title":"Chromatotec airmoVOC BTX","description":"\n\u003c!-- PDF Documents --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/tsp_a21_airmoVOC_BTX_MCERTS.pdf?v=1793685208\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eAIRMO VOC BTX TECHNICAL DATA SHEET\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/EN14662_MCERTS_certificate_airmoVOC_2023.pdf?v=1793685207\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eEN14662 MCERTS CERTIFICATE\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003c!-- Description --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: #0d0c0c;\"\u003eDescription\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch3\u003eAnalysis of Benzene, Toluene, Ethylbenzene, o,m,p Xylene, Styrene\u003c\/h3\u003e\n\n\u003cp\u003eA GC\/FID instrument for BTEX monitoring in air, water and soil\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eDescription :\u003c\/strong\u003e\u003cbr\u003e\n  The airmoVOC BTX is a gas chromatograph for the analysis and monitoring of trace amounts of benzene, toluene, ethylbenzene (m\/p\/o) xylene by FID detection.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003ePrincipal :\u003c\/strong\u003e\u003cbr\u003e\n  Automatic sampling and concentration using an absorbent trap. Desorption from the trap and injection into a metallic capillary column regulated by a temperature gradient. The H2 pressure at the column head is controlled by a piezo valve.\u003cbr\u003e\n  The detection of all compounds eluting from the column is performed by a FID detector\n\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eCharacteristics :\u003c\/strong\u003e\u003cbr\u003e\n  The airmoVOC BTX is equipped with an integrated PC comprising of the Vistachrom programme. The internal calibration allows automatic validation of results. (Certified Benzene tube at ± 10%).\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The instrument is robust, compact and very low maintenance and offers excellent result quality : repeatability, linearity, stability and sensibility (ppt).\n\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eMCERTS certified analyzer for benzene measurement following EN 14662-3\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eVISTACHROM ® software :\u003c\/strong\u003e\u003cbr\u003e\n  Chromatotec developed software system allows :\n\u003c\/p\u003e\n\n\u003cul class=\"description\"\u003e\n  \u003cli\u003eRemote monitoring\u003c\/li\u003e\n  \u003cli\u003eFull traceability through archiving of results and QC\u003c\/li\u003e\n  \u003cli\u003eSet up and control of threshold alarms\u003c\/li\u003e\n  \u003cli\u003eExport of data MODBUS \/ MGS1 \/ 4-20mA \/0-10V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003ch6\u003eTechnical Data\u003c\/h6\u003e\n\n\u003ctable class=\"product_layout_27\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth class=\"product_layout_26\" colspan=\"2\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eBTEX Analysis\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u003cstrong\u003e8 compounds with 7 peaks:\u003c\/strong\u003e\u003cbr\u003e\n          Benzene, Toluene, Ethylbenzene, M+P Xylene, O Xylene, Cyclohexane* and Styrene*\u003cbr\u003e\n          \u003cstrong\u003eMore VOCs in option:\u003c\/strong\u003e\u003cbr\u003e\n          Naphtalene, Phenol, 1.3 Butadiene\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDetection Limit\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Benzene \u0026lt; 20 ppt or 0,064 µg\/m3\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDetection Range\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          0,1 to 380 µg\/m3 for Benzene\u003cbr\u003e\n          Standard amibient air monitoring 0 to 50 µg\/m3\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eRelative Standard Deviation\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u0026lt; 0.3 % over 48 h (retention time)\u003cbr\u003e\n          \u0026lt; 3 % over 48 h (concentration)\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eResults\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Full result storage (data and chromatogram)\u003cbr\u003e\n          Embedded computer Windows® based with LCD display\u003cbr\u003e\n          128 GB of Hardware storage on SSD memory\u003cbr\u003e\n          4 USB Connecting Port\u003cbr\u003e\n          Two RS-232 ports\u003cbr\u003e\n          Display: 10’’ TFT Color LCD\u003cbr\u003e\n          MODBUS RTU \/ JBUS communication protocol\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eCycle Time\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          15, 20 or 30 min (A21022 BTEX Mcerts)\u003cbr\u003e\n          30 min (A21022 BTEX-B Mcerts)\u003cbr\u003e\n          20 min (A26022)\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eGas Supply\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          H2 (FID and carrier gas): 30 ml\/min (supply 2 bar ; 1\/18’’ double ferrule\u003cbr\u003e\n          Air (FID) : 180 ml\/min (supply 3 bar ; 1\/8’’double ferrule\u003cbr\u003e\n          Sample supply (sample pump) 1\/4’’double ferrule\u003cbr\u003e\n          Pneumatic valve 90ml\/commutation\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"DiamondSci","offers":[{"title":"Default Title","offer_id":50104072667395,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/face_avant_airmoBTX_5U_option_four_colonne_img_5182-Medium-copie.webp?v=1793685396"},{"product_id":"chromatotec-µ-airtoxic","title":"Chromatotec µ-airTOXIC","description":"\n\u003c!-- PDF Document --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/TSP_micro-airTOXIC.pdf?v=1793685543\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eMICRO-AIRTOXIC TECHNICAL DATA SHEET\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003c!-- Product Description --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: #0d0c0c;\"\u003eDescription\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch3\u003ePortable GC-PID VOC Analyzer\u003c\/h3\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eµ-airTOXIC\u003c\/strong\u003e is a portable\n  \u003cstrong\u003eGC-PID analyzer with pre-concentration\u003c\/strong\u003e\n  for trace-level VOC monitoring. Multiple configurations cover\n  BTEX, 1,3-butadiene and VOCs from C3 to C12, according to\n  the selected method.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The C6-C12 versions include a PAMS configuration for\n  \u003cstrong\u003e33 VOCs\u003c\/strong\u003e and a European configuration for\n  \u003cstrong\u003e45 VOCs\u003c\/strong\u003e, including terpenes. Optional method\n  libraries extend the available applications.\n\u003c\/p\u003e\n\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cul class=\"description\"\u003e\n  \u003cli\u003eAir-quality monitoring in urban areas, environmental monitoring and refinery fence lines.\u003c\/li\u003e\n  \u003cli\u003eIndoor and outdoor air, industrial hygiene and CO₂ beverages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOperating Principle and Field Deployment\u003c\/h4\u003e\n\n\u003cp\u003e\n  An electrical six-port valve, a single adsorbent trap and a\n  capillary column are combined with a heated PID and a 10.6 eV\n  lamp. Temperature programming of the column oven and\n  carrier-gas pressure\/flow control support the selected\n  analytical method.\n\u003c\/p\u003e\n\n\u003cul class=\"description\"\u003e\n  \u003cli\u003e\n    The portable suitcase integrates sampling, analysis,\n    data storage, a battery and an internal nitrogen tank,\n    with readiness for operation in less than 5 minutes.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Integrated Wi-Fi enables control from a phone, tablet\n    or laptop. A local touchscreen is optional.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Vistachrom LITE provides measurement configuration,\n    calibration, recalculation, data storage and export.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions\u003c\/h4\u003e\n\n\u003cul class=\"description\"\u003e\n  \u003cli\u003e\n    Portable permeation oven with certified permeation\n    tubes for calibration; nitrogen generator up to\n    300 mL\/min with an external compressor for operation\n    and\/or tank refilling, providing up to 10 hours of\n    operation after refilling.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Modem support and remote control; purge module for\n    extracting VOCs from water for online BTEX analysis;\n    additional battery.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Rechargeable internal high-pressure carrier-gas\n    cylinder up to 150 barg; external nitrogen bottle\n    for up to 20 days of operation at 70 bar.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Multiple methods with a VOC library of more than\n    40 compounds (µ-airTOXIC C6-C12). Biogenic measurement,\n    including isoprene, is available, with potential\n    co-elution of C4 or C5 ozone VOC precursors.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eApplication-dependent Compliance\u003c\/h4\u003e\n\n\u003cp\u003e\n  The TSP states support for compliance with\n  \u003cstrong\u003eEN 14662-3:2015 for selected applications\u003c\/strong\u003e\n  and lists EN 15267-1, EN 15267-2 and QAL1.\n  Applicability depends on the selected configuration and\n  application; refer to the TSP for details.\n\u003c\/p\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003ch6\u003eTechnical Data\u003c\/h6\u003e\n\n\u003ctable class=\"product_layout_27\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth class=\"product_layout_26\" colspan=\"2\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eConfigurations and Compounds\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u003cstrong\u003eBTEX:\u003c\/strong\u003e Benzene, Cyclohexane, Toluene,\n          Ethylbenzene, m- and p-Xylenes, Styrene and o-Xylene.\n          1,3-butadiene, IAA or naphthalene are optional.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eC6-C12 PAMS:\u003c\/strong\u003e 33 VOCs from benzene to\n          n-undecane.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eEuropean C6-C12 configuration:\u003c\/strong\u003e\n          45 VOCs from benzene to n-decane, including biogenic\n          VOCs (terpenes). Other method libraries, such as\n          C3-C10, are optional.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDetection and Linearity\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u003cstrong\u003eAutomatic-mode LDL:\u003c\/strong\u003e ≤ 10 ppt.\n          The TSP cites benzene or other VOCs (µ-A76022);\n          performance depends on compound and configuration.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eBenzene ranges:\u003c\/strong\u003e 0-10 ppb,\n          0-100 ppb or 0-1000 ppb.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eArea linearity:\u003c\/strong\u003e R² \u0026gt; 0.995.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eRepeatability\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Relative standard deviation over 48 hours:\n          better than 1% for retention time; better than\n          2% for concentration at 1 ppb.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eCycle Times\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          10, 15, 20 or 30 minutes (µ-A73022);\n          30 minutes (µ-A73022-B).\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eSampling and Carrier Gas\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u003cstrong\u003eProgrammable sample volume:\u003c\/strong\u003e\n          20 to 700 mL or more.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eBTEX and C6-C12 carrier-gas consumption:\u003c\/strong\u003e\n          minimum 3 mL\/min with an electric injection valve;\n          varies with column internal diameter and application.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eInternal nitrogen tank:\u003c\/strong\u003e\n          up to 15 barg. Analysis up to 22 hours at 15 bar.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDetector and Column\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Heated photoionization detector (PID) with a\n          10.6 eV lamp.\n          \u003cbr\u003e\u003cbr\u003e\n          Electrical six-port valve, single adsorbent trap\n          and capillary column. Programmed column-oven\n          temperature gradient up to 200°C, with\n          carrier-gas pressure\/flow control.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eOperating Temperature\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          0°C to 40°C; may vary with the method used.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003ePower and Battery\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          12 V DC; battery autonomy up to 8 hours,\n          depending on the method used.\n          \u003cbr\u003e\u003cbr\u003e\n          Battery rechargeable from 230 V \/ 110 V,\n          50 Hz \/ 60 Hz.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDimensions and Weight\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Height: 410 mm; width: 340 mm; depth: 180 mm.\n          Net weight: 7 kg.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eSoftware, Storage and Communication\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Vistachrom LITE on Linux; Wi-Fi, Ethernet\n          and one USB port.\n          \u003cbr\u003e\u003cbr\u003e\n          Standard data capacity: 16 GB. Internal data storage\n          up to 10 years; data transfer via USB.\n          \u003cbr\u003e\u003cbr\u003e\n          Measurement configuration, calibration,\n          recalculation and export; retention-time,\n          area, mass and concentration profiles.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eTablet Specifications\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          8.7-inch display, 1340 × 800 resolution;\n          Android operating system; shock protection included.\n          \u003cbr\u003e\u003cbr\u003e\n          Approximately 14 hours of continuous use\n          and approximately 335 g. Characteristics may vary.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"DiamondSci","offers":[{"title":"Default Title","offer_id":50104095113475,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/micro-airtoxic-with-tablet.png?v=1793685633"}],"url":"https:\/\/diamondsci.com\/collections\/chromatotec.oembed","provider":"DiamondSci","version":"1.0","type":"link"}