{"product_id":"chlorine-chlorine-dioxide","title":"Cl2 – ClO2 sensor","description":"\u003ch2\u003e\n  \u003cspan style=\"color: #fa0b0b;\"\u003e*\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/Cl2-ClO2.pdf?v=1792739190\" rel=\"noopener\" target=\"_blank\" style=\"color: #fa0b0b;\"\u003e\n      \u003cu\u003eDownload datasheet\u003c\/u\u003e\n    \u003c\/a\u003e\n  *\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003cdiv class=\"pro_inner_rit\" style=\"font-family: Verdana, sans-serif; font-size: 14px; line-height: 1.6;\"\u003e\n\n  \u003ch2\u003eWhere are they found?\u003c\/h2\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    \u003cstrong\u003eChlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e is a greenish-yellow gas\n    with a strong, irritating odour. It is highly reactive and classified\n    as a toxic gas. Cl\u003csub\u003e2\u003c\/sub\u003e is not flammable, but it is an\n    oxidising agent, meaning it can intensify fires when in contact\n    with combustible materials.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    \u003cstrong\u003eChlorine dioxide (ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/strong\u003e is a reddish-yellow\n    gas with a pungent chlorine-like odour. It is a strong oxidising\n    agent. Though effective in microbial control, it is also a toxic\n    air pollutant and regulated due to its potential health and\n    environmental impacts.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    Neither Cl\u003csub\u003e2\u003c\/sub\u003e nor ClO\u003csub\u003e2\u003c\/sub\u003e are naturally present,\n    but they are widely present in industrial processes. Their presence\n    in the environment is mainly due to human activity in the paper\n    and textile industry, wastewater treatment plants (WWTP)\n    and chemical manufacturing.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eWhy are they harmful?\u003c\/h2\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    Both Cl\u003csub\u003e2\u003c\/sub\u003e and ClO\u003csub\u003e2\u003c\/sub\u003e are highly toxic and pose\n    serious health and environmental hazards.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    Their inhalation can cause severe irritation of the respiratory\n    tract, coughing and pulmonary edema, while contact with the skin\n    or eyes leads to painful burns and tissue damage. Chronic exposure\n    may result in long-term respiratory conditions.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    Environmentally, they are extremely harmful to aquatic organisms.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eCl\u003csub\u003e2\u003c\/sub\u003e – ClO\u003csub\u003e2\u003c\/sub\u003e cartridge\u003c\/h2\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    The Cl\u003csub\u003e2\u003c\/sub\u003e – ClO\u003csub\u003e2\u003c\/sub\u003e cartridge has a built-in\n    electrochemical sensor capable of measuring both Cl\u003csub\u003e2\u003c\/sub\u003e\n    and ClO\u003csub\u003e2\u003c\/sub\u003e pollutants, from low concentrations (ppb level)\n    to high concentrations. The cartridge is calibrated against\n    Cl\u003csub\u003e2\u003c\/sub\u003e, while the response to ClO\u003csub\u003e2\u003c\/sub\u003e is higher\n    than 70%.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-weight: normal;\"\u003e\n    This dual cartridge is an excellent option for measuring chlorine\n    compounds when coexisting in the same applications (WWTP,\n    disinfection applications, etc.), offering high stability,\n    fast response and recovery, and robustness under environmental\n    conditions, making it an excellent cartridge for industrial monitoring.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\n  \u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Verdana, sans-serif; font-size: 14px;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eType\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eElectrochemical\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eUnit of measurement\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003emg\/m\u003csup\u003e3\u003c\/sup\u003e, ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eMeasurement range \u003csup\u003e(1)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e0–20 ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eResolution \u003csup\u003e(2)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e0.01 ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eOperating temperature range \u003csup\u003e(3)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e-20 to 50 °C\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eOperating RH range \u003csup\u003e(4)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e0 to 99 %RH\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eRecommended RH range \u003csup\u003e(5)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e15 to 90 %RH\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eOperating life \u003csup\u003e(6)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e\u0026gt; 24 months\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eGuarantee range \u003csup\u003e(7)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e250 ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eLimit of Detection (LOD) \u003csup\u003e(8)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e0.01 ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eRepeatability \u003csup\u003e(9)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e—\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eResponse time \u003csup\u003e(10)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e\u0026lt; 60 sec\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eTypical accuracy \u003csup\u003e(12)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e± 0.03 ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eTypical precision R\u003csup\u003e2\u003c\/sup\u003e \u003csup\u003e(11)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e—\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eTypical slope \u003csup\u003e(11)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e—\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eTypical intercept (a) \u003csup\u003e(11)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e—\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eDQO - Typical U(exp) \u003csup\u003e(13)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e—\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003eTypical intra-model variability \u003csup\u003e(14)\u003c\/sup\u003e\n\u003c\/td\u003e\n          \u003ctd style=\"border: 1px solid #999; padding: 10px;\"\u003e\u0026lt; 0.01 ppm\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"font-size: 12px; margin-top: 24px; line-height: 1.7;\"\u003e\n    \u003col\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eMeasurement range:\u003c\/strong\u003e\n        Concentration range measured by the sensor.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eResolution:\u003c\/strong\u003e\n        Smallest unit of measurement that can be indicated by the sensor.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eOperating temperature range:\u003c\/strong\u003e\n        Temperature interval at which the sensor is rated to operate safely\n        and provide measurements. In the PM sensor Type A: -40 to 50 °C\n        with heater (more information on this version on request).\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eOperating RH range:\u003c\/strong\u003e\n        Humidity interval at which the sensor is rated to operate safely\n        and provide measurements.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eRecommended RH range:\u003c\/strong\u003e\n        Recommended relative humidity range for optimal sensor performance.\n        Continuous exposure outside the recommended range may damage the cartridge.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eOperating life:\u003c\/strong\u003e\n        Time period during which the sensor can operate effectively and\n        accurately under normal conditions.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eGuarantee range:\u003c\/strong\u003e\n        Concentration range covered by Kunak's guarantee.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eLOD (Limit of Detection):\u003c\/strong\u003e\n        Measured at laboratory conditions at 20 °C and 50% RH.\n        The limit of detection is the minimum concentration that can be\n        detected as significantly different to zero gas concentration,\n        calculated according to the Technical Specification CEN\/TS 17660.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eRepeatability:\u003c\/strong\u003e\n        Measured at laboratory conditions at 20 °C and 50% RH.\n        Closeness of the agreement between the results of successive\n        measurements of the same measurand carried out under the same\n        conditions of measurement, calculated according to the\n        Technical Specification CEN\/TS 17660.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eResponse time:\u003c\/strong\u003e\n        Time needed by the sensor to reach 90% of the final stable value.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eTypical precision – R\u003csup\u003e2\u003c\/sup\u003e, slope and intercept:\u003c\/strong\u003e\n        Statistics obtained between the device hourly measurements and\n        reference instruments in field tests between -10 to +30 °C\n        at different locations. For the type B PM sensor, the expected\n        error for PM\u003csub\u003e10\u003c\/sub\u003e is higher in the presence of coarse particles.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eTypical accuracy:\u003c\/strong\u003e\n        For criteria pollutants, this is the average Mean Absolute Error\n        (MAE) obtained between the device hourly measurements and reference\n        instruments for 1 to 8 months of field tests between -10 to +30 °C\n        in different countries. For other pollutants, it is the expected\n        error of the measurement at the reading.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eDQO - Typical U(exp):\u003c\/strong\u003e\n        Data Quality Objective expressed as the Expanded Uncertainty in the\n        Limit Value obtained between the device hourly measurements and\n        reference instruments for 1 to 8 months of field tests between\n        -10 to +30 °C in different countries, calculated according to\n        the European Air Quality Directive 2024\/2881 and the Technical\n        Specification CEN\/TS 17660. For the type B PM sensor, the expected\n        error for PM\u003csub\u003e10\u003c\/sub\u003e is higher in the presence of coarse particles.\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        \u003cstrong\u003eTypical intra-model variability:\u003c\/strong\u003e\n        Calculated as the standard deviation of the three sensor means\n        in 1 to 8 months of field tests between -10 to +30 °C\n        in different countries.\n      \u003c\/li\u003e\n    \u003c\/ol\u003e\n\n    \u003cp\u003e\n      \u003cstrong\u003eA, B, C, D superindex:\u003c\/strong\u003e\n      The super indexes refer to different types of cartridges related\n      to the same target pollutant but with different technical specifications.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"DiamondSci","offers":[{"title":"Default Title","offer_id":49958033260803,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/Cl2-ClO2_jpg.webp?v=1792739105","url":"https:\/\/diamondsci.com\/products\/chlorine-chlorine-dioxide","provider":"DiamondSci","version":"1.0","type":"link"}