{"product_id":"chromatotec-µ-airtoxic","title":"Chromatotec µ-airTOXIC","description":"\n\u003c!-- PDF Document --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: rgb(251, 9, 9);\"\u003e\n    * \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/TSP_micro-airTOXIC.pdf?v=1793685543\" style=\"color: rgb(251, 9, 9);\" rel=\"noopener\" target=\"_blank\"\u003eMICRO-AIRTOXIC TECHNICAL DATA SHEET\u003c\/a\u003e *\n  \u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003c!-- Product Description --\u003e\n\u003ch2\u003e\n  \u003cspan style=\"color: #0d0c0c;\"\u003eDescription\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003ch3\u003ePortable GC-PID VOC Analyzer\u003c\/h3\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eµ-airTOXIC\u003c\/strong\u003e is a portable\n  \u003cstrong\u003eGC-PID analyzer with pre-concentration\u003c\/strong\u003e\n  for trace-level VOC monitoring. Multiple configurations cover\n  BTEX, 1,3-butadiene and VOCs from C3 to C12, according to\n  the selected method.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The C6-C12 versions include a PAMS configuration for\n  \u003cstrong\u003e33 VOCs\u003c\/strong\u003e and a European configuration for\n  \u003cstrong\u003e45 VOCs\u003c\/strong\u003e, including terpenes. Optional method\n  libraries extend the available applications.\n\u003c\/p\u003e\n\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cul class=\"description\"\u003e\n  \u003cli\u003eAir-quality monitoring in urban areas, environmental monitoring and refinery fence lines.\u003c\/li\u003e\n  \u003cli\u003eIndoor and outdoor air, industrial hygiene and CO₂ beverages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOperating Principle and Field Deployment\u003c\/h4\u003e\n\n\u003cp\u003e\n  An electrical six-port valve, a single adsorbent trap and a\n  capillary column are combined with a heated PID and a 10.6 eV\n  lamp. Temperature programming of the column oven and\n  carrier-gas pressure\/flow control support the selected\n  analytical method.\n\u003c\/p\u003e\n\n\u003cul class=\"description\"\u003e\n  \u003cli\u003e\n    The portable suitcase integrates sampling, analysis,\n    data storage, a battery and an internal nitrogen tank,\n    with readiness for operation in less than 5 minutes.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Integrated Wi-Fi enables control from a phone, tablet\n    or laptop. A local touchscreen is optional.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Vistachrom LITE provides measurement configuration,\n    calibration, recalculation, data storage and export.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions\u003c\/h4\u003e\n\n\u003cul class=\"description\"\u003e\n  \u003cli\u003e\n    Portable permeation oven with certified permeation\n    tubes for calibration; nitrogen generator up to\n    300 mL\/min with an external compressor for operation\n    and\/or tank refilling, providing up to 10 hours of\n    operation after refilling.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Modem support and remote control; purge module for\n    extracting VOCs from water for online BTEX analysis;\n    additional battery.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Rechargeable internal high-pressure carrier-gas\n    cylinder up to 150 barg; external nitrogen bottle\n    for up to 20 days of operation at 70 bar.\n  \u003c\/li\u003e\n  \u003cli\u003e\n    Multiple methods with a VOC library of more than\n    40 compounds (µ-airTOXIC C6-C12). Biogenic measurement,\n    including isoprene, is available, with potential\n    co-elution of C4 or C5 ozone VOC precursors.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eApplication-dependent Compliance\u003c\/h4\u003e\n\n\u003cp\u003e\n  The TSP states support for compliance with\n  \u003cstrong\u003eEN 14662-3:2015 for selected applications\u003c\/strong\u003e\n  and lists EN 15267-1, EN 15267-2 and QAL1.\n  Applicability depends on the selected configuration and\n  application; refer to the TSP for details.\n\u003c\/p\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003ch6\u003eTechnical Data\u003c\/h6\u003e\n\n\u003ctable class=\"product_layout_27\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth class=\"product_layout_26\" colspan=\"2\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eConfigurations and Compounds\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u003cstrong\u003eBTEX:\u003c\/strong\u003e Benzene, Cyclohexane, Toluene,\n          Ethylbenzene, m- and p-Xylenes, Styrene and o-Xylene.\n          1,3-butadiene, IAA or naphthalene are optional.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eC6-C12 PAMS:\u003c\/strong\u003e 33 VOCs from benzene to\n          n-undecane.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eEuropean C6-C12 configuration:\u003c\/strong\u003e\n          45 VOCs from benzene to n-decane, including biogenic\n          VOCs (terpenes). Other method libraries, such as\n          C3-C10, are optional.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDetection and Linearity\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u003cstrong\u003eAutomatic-mode LDL:\u003c\/strong\u003e ≤ 10 ppt.\n          The TSP cites benzene or other VOCs (µ-A76022);\n          performance depends on compound and configuration.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eBenzene ranges:\u003c\/strong\u003e 0-10 ppb,\n          0-100 ppb or 0-1000 ppb.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eArea linearity:\u003c\/strong\u003e R² \u0026gt; 0.995.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eRepeatability\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Relative standard deviation over 48 hours:\n          better than 1% for retention time; better than\n          2% for concentration at 1 ppb.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eCycle Times\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          10, 15, 20 or 30 minutes (µ-A73022);\n          30 minutes (µ-A73022-B).\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eSampling and Carrier Gas\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          \u003cstrong\u003eProgrammable sample volume:\u003c\/strong\u003e\n          20 to 700 mL or more.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eBTEX and C6-C12 carrier-gas consumption:\u003c\/strong\u003e\n          minimum 3 mL\/min with an electric injection valve;\n          varies with column internal diameter and application.\n          \u003cbr\u003e\u003cbr\u003e\n          \u003cstrong\u003eInternal nitrogen tank:\u003c\/strong\u003e\n          up to 15 barg. Analysis up to 22 hours at 15 bar.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDetector and Column\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Heated photoionization detector (PID) with a\n          10.6 eV lamp.\n          \u003cbr\u003e\u003cbr\u003e\n          Electrical six-port valve, single adsorbent trap\n          and capillary column. Programmed column-oven\n          temperature gradient up to 200°C, with\n          carrier-gas pressure\/flow control.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eOperating Temperature\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          0°C to 40°C; may vary with the method used.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003ePower and Battery\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          12 V DC; battery autonomy up to 8 hours,\n          depending on the method used.\n          \u003cbr\u003e\u003cbr\u003e\n          Battery rechargeable from 230 V \/ 110 V,\n          50 Hz \/ 60 Hz.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eDimensions and Weight\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Height: 410 mm; width: 340 mm; depth: 180 mm.\n          Net weight: 7 kg.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eSoftware, Storage and Communication\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          Vistachrom LITE on Linux; Wi-Fi, Ethernet\n          and one USB port.\n          \u003cbr\u003e\u003cbr\u003e\n          Standard data capacity: 16 GB. Internal data storage\n          up to 10 years; data transfer via USB.\n          \u003cbr\u003e\u003cbr\u003e\n          Measurement configuration, calibration,\n          recalculation and export; retention-time,\n          area, mass and concentration profiles.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003eTablet Specifications\u003c\/span\u003e\n      \u003c\/td\u003e\n      \u003ctd valign=\"top\"\u003e\n        \u003cspan style=\"font-family: Verdana;\"\u003e\n          8.7-inch display, 1340 × 800 resolution;\n          Android operating system; shock protection included.\n          \u003cbr\u003e\u003cbr\u003e\n          Approximately 14 hours of continuous use\n          and approximately 335 g. Characteristics may vary.\n        \u003c\/span\u003e\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"DiamondSci","offers":[{"title":"Default Title","offer_id":50104095113475,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0631\/2414\/4387\/files\/micro-airtoxic-with-tablet.png?v=1793685633","url":"https:\/\/diamondsci.com\/products\/chromatotec-%c2%b5-airtoxic","provider":"DiamondSci","version":"1.0","type":"link"}