SWG-100 Biogas Compact
Free 30 Day Returns
The SWG-100 Compact is a cost effective stationary biogas analyzer designed for discontinuous measurement. It has user programmable settings for up to 24 measurements per 24 hours. It is typically used in the harsh industrial environments of combined heat and power (CHP) engine gas monitoring.
Basic Equipment
- Plug & play, pre-calibrated sensors
- Safety in use with gas flow restrictor orifice at gas inlet and ventilation
- Efficient sample gas preparation for fast and reliable measurements
- Sampling from low suction up to high pressure gas
- No dilution of the sample gas, neither use of compressed air is required
- Discontinuous measurement, user settable up to 24 measurements per 24 hours
- Up to 2 sites monitoring (time sharing technique) with only one analyzer
- Data storage and event logging on SD card
- IP 54 cabinet for use in harsh environment
- Ready to run delivery, minimum installation work, low service downtime
- May be installed outside or inside
No Data Available
Technical
| Measuring ranges | |
| O2 – Oxygen | 0 … 25 % (electro-chemical sensor) |
| CO2 – Carbon dioxide | 0 … 100% NDIR |
| CH4 – Methane | 0 … 100% NDIR |
| H2S – Hydrogen sulfide | 0 ….. 2,000 ppm / 5,000ppm overload (electro-chemical sensor) |
| Dimensions and other data | |
| Operating temperature | 41°F …113°F (+5°C…+45°C) or -4°F …113°F (-20°C…+45°C) with cabinet heater |
| Power supply | Universal 90 – 240 Vac / 47 – 63 Hz / 90 W (150 W with cabinet heater) |
| Display | 3.5″ TFT color display with backlight |
| Dimensions | 15.74” x 19.68” x 11.81” (400x500x300 mm) (WxHxD) wall or rack mounting |
| Weight | approx. 31 lbs. (14 kg) |
| Protection class | IP 54 |
No data Available
2. Does it need to be installed under a canopy or shaded area?
The recommended/provided tubing size is as follows (Teflon (PTFE) gas sampling line - 0.16"/0.24" 3.28' (DN4/6mm, 1m length) (MAX 200 meters) @ $12.00/m). SS tubing in the same dimensions is absolutely acceptable and widely used as well. Heat tracing can certainly be helpful, mainly in colder environments where condensate freezing within sample lines is possible/expected. Otherwise the condensate auto-drains that are external to the unit, and when installed as close as possible to the unit will remove 99.9% of moisture before entering the unit. Inside the unit, there is additional condensate removal via a continuous peristaltic pump system.
4. Can you quote a 115VAC power supply?
Absolutely, no problem at all. There is no price change; it is just as simple as leaving a note on the order.
5. Does it require any calibration or carrier gas that we have to provide?
Though it's not a requirement, unless you wish to set-up auto-calibration, we can also provide calibration gas if desired, as it can be helpful to have on hand. Typically, we include one cylinder of a 60%CH4/40%CO2/500ppm H2S mix for units that include an H2S sensor when we quote for the start-up/commissioning or calibration/repair service. But we can quote any mix or cylinder size you may be interested in.