by DiamondSci
SKU O2NE
GTIN : 29229059
Sensor specifications:
Measurement technique: 02-partial pressure electrochemical cell with atmospheric pressure compensation
Range: Alarms: 02:0.1 to 25.0% 18.0% Alarm
Accuracy: 19.5% Alarm
Better than ± 0.75% 02 over 5.0 to 25.0% 02 Better than ± 1.00% 02 over 0.1 to 5.0% 02
Expected sensor life: 10 years
Sensor warranty: 2 years
Analyzer specifications:
Analyzer type: Fixed
Supply voltage: 230V AC, 110V AC, 9 to 24V DC
Operating temp: 0 to 40 °C
Power consumption: < 5 Watts
Dimensions:
Analyzer 175 x 110 x 75mm Repeater 72 x 170 x 45mm
IP Rating:
Analyzer 1P65
Repeater IP65 (quick connect IP43)
Sounder : 85dbA @ 10cm
Options: 4 to 20mA, 0 to 1V, 2 x relays
Warranty: 2 years
Approvals:
EMC Directive 89/336/EEC (EN50270:1999, EN61000- 6-3:2001+A11:2004)
Low Voltage Directive 73/23/EEC (BS EN 61010-1:2001, IEC 61010-1(2ed))
AS61010.1-2003 (Australia & New Zealand)
CSA (cCSAus), Master Contract 239512,
Certificate 1909026
*other measurement units are available
We reserve the right to upgrade, develop or change specifications without prior notice. Full Technical Specifications are available upon request.